Connecting Waterpeople
Autodesk Water Webinar Series returns: 10 Oct, 15:30 CEST
ACCIONA

You are here

ACCIONA develops a solution to prevent fouling in reverse osmosis membranes

  • ACCIONA develops solution to prevent fouling in reverse osmosis membranes
  • The new biological indicator will be integrated into a predictive tool based on Artificial Intelligence which will allow identifying the potential fouling of the inlet water.

About the entity

ACCIONA
The water business of ACCIONA concentrates on water treatment and reverse osmosis desalination, a technology in which it is the world leader.

ACCIONA , as part of its commitment with innovation, has launched the WITNESS project, which objective is to develop a biological indicator to preventively determine the presence of agents causing fouling in seawater reverse osmosis desalination processes.

Fouling in reverse osmosis membranes is one of the main limitations to further optimise seawater reverse osmosis desalination processes, as well as one of the great challenges for the sector.

The fouling of membranes leads to higher operation pressure and thus and increase of energy consumption, as well as greater complexity in operation and a reduction in the permeate quality.

Current indicators do not allow distinguishing between different fouling types and have limitations regarding representativeness, such as the Silt Density Index (SDI) (Schippers et al., 2014). In addition, current biological indicators include incomplete or biased measurements which prevent from having a complete overview of the fouling potential of a given seawater matrix (Alhadidi et al., 2012; Lee Jin-Wook et al., 2010). According to several sources of information biological fouling may cause up to 10-30% of the issues in reverse osmosis membranes in desalination, with the economic impact on CapEx and OpEX that this entails.

According to several sources of information biological fouling may cause up to 10-30% of the issues in reverse osmosis membranes in desalination

The new indicator developed by ACCIONA will provide a preventive diagnosis to adjust the operating conditions of the desalination plants, in order to minimize fouling and, therefore, its consequences on the desalination process.

Together with other operation indicators of the reverse osmosis stage, the WITNESS indicator will be integrated into an Artificial Intelligence-based fouling potential prediction tool, which will be validated in the innovation facilities of the company, specifically in its Leading Experimental Accelerator in Desalination (LEAD®), located in the San Pedro del Pinatar II SWRO (Murcia).

Likewise, a base case version will be developed and, afterwards, an augmented version of the Artificial Intelligence tool that will allow to carry out predictive estimations of the potential fouling level.

Subscribe to our newsletter

Topics of interest

The data provided will be treated by iAgua Conocimiento, SL for the purpose of sending emails with updated information and occasionally on products and / or services of interest. For this we need you to check the following box to grant your consent. Remember that at any time you can exercise your rights of access, rectification and elimination of this data. You can consult all the additional and detailed information about Data Protection.

Featured news